UFx.py version 1.6 from 07/16/2018
Page 1 of 2
Created by user vjeran on 07/17/2018 14:03:04
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Calibration |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+Bx\Final Results\Stretched Wire |
Date : | 06-26-2018 |
Time : | 13:16:05 - 14:21:00 |
Operator : | VV |
Project : | DUMMY |
Device Type : | Phase Shifter |
Run Number : | 1 |
Data Type : | |
Run Comment : | rewired; 126 Gauss*cm magnet (Bx positive) |
gap | I1Y | I2Y | I1X | I2X |
- |
-11.4 0.6 (5) |
-3.1 0.7 (5) |
121.8 0.1 (5) |
25.5 0.3 (5) |
integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
I1Y |
- |
-14.7 3.4 (3) |
-13.1 0.2 (3) |
-12.8 0.3 (3) |
-12.3 1.4 (3) |
-13.0 0.1 (3) |
I2Y |
- |
-3.2 0.2 (3) |
-3.6 0.2 (3) |
-3.5 0.3 (3) |
-3.5 0.1 (3) |
-3.6 0.3 (3) |
I1X |
- |
113.9 14.2 (3) |
100.0 0.0 (1) |
110.3 18.0 (2) |
111.2 15.9 (2) |
98.8 1.7 (2) |
I2X |
- |
23.2 2.3 (2) |
24.8 0.1 (3) |
23.1 2.2 (2) |
25.0 0.1 (3) |
23.7 1.9 (3) |
integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
I1Y |
- |
-11.3 0.8 (3) |
-10.9 0.9 (3) |
-11.1 1.1 (3) |
-11.2 0.6 (3) |
-11.1 0.9 (3) |
I2Y |
- |
-3.2 0.2 (3) |
-3.0 0.1 (3) |
-3.3 0.2 (3) |
-2.9 0.2 (3) |
-3.1 0.2 (3) |
I1X |
- |
121.3 0.7 (3) |
119.8 0.3 (3) |
120.7 1.0 (3) |
121.2 2.4 (3) |
119.9 0.5 (3) |
I2X |
- |
25.0 0.4 (3) |
24.8 0.2 (3) |
24.8 0.1 (3) |
25.0 0.4 (3) |
24.8 0.2 (3) |
UFx.py version 1.6 from 07/16/2018
Page 2 of 2
Created by user vjeran on 07/17/2018 14:03:04
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Calibration |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+Bx\Final Results\Stretched Wire |